⎝⎛炸金花⎞⎠


Cardiopulmonary resuscitation modelCardiopulmonary resuscitation dummyCardiopulmonary resuscitation modelHuman cardiopulmonary resuscitation training

2019-11-05 15:12:46 Click: 168
Advanced fully automatic CPR Simulator




The main function:

Executive Standards: The latest edition of the American Heart Association (AHA) 2015 International Cardiopulmonary Resuscitation (CPR) and Cardiovascular Emergency (ECC) Guidelines. Teaching training process: CAB; that is: chest compressions-airway-breathing.

Composition: CPR teaching simulator and CPR control display.

The main functions and characteristics of CPR teaching simulator:

◎ High-molecular materials, durable, component-type assembly, easy to disassemble, easy to sterilize, easy to clean, and not deformed; the model has fine workmanship and accurate and realistic anatomical marks.

◎ Simulation of the height of the human body is coordinated with the simulation of the height of the adult.

◎ Training airway is open.

◎ Compared with human pupil simulation, pupils dilated before first aid, and returned to normal after successful first aid.

◎ Carotid artery pulsation test. During the emergency treatment, the carotid artery beats with the same rhythm as the compression frequency. After successful rescue, the carotid artery pulsates.

◎ The simulated nipple marks and rib mastoid marks better train the compression position.

◎ Stomach thoracic bulge can be observed in simulated human abdomen.

CPR control display function:

◎ Digital display: The correct and wrong times of chest compressions and artificial respiration are recorded in detail.

◎ Voice prompt: During the model first aid, real-time voice prompts for tidal volume and chest compression depth, the sound size can be freely adjusted, and during the assessment process, the voice prompt is turned off.

◎ Column-shaped indicator shows: real-time monitoring of tidal volume and chest compression depth, too large and too small are reminded in red and yellow, green is the appropriate amount.

◎ Counting time unit: S.

◎ Operation method: training, assessment and custom assessment.

◎ Pressing frequency: 2015AHA latest standard, that is ≥100-120 times / min.

◎ Cardiopulmonary resuscitation chest compression and artificial respiration ratio: 30: 2.

◎ The pupil and carotid pulse can be adjusted freely.

◎ Shield error display count.

◎ Press frequency setting can be adjusted.

Printer functions:

◎ Print the operation process after the operation.
◎ Transcript content covers operation mode, consciousness judgment, emergency breathing, pulse check, breathing check, removal of foreign bodies, operating frequency, compression and blowing ratio, number of cycles,

按压正确/错误次数、按压错误的原因和次数、吹气正确/错误的原因和次数、 Number of presses and blows per cycle operation, number of correct / wrong presses, cause and number of press errors, cause and number of correct / wrong blows,

Causes of blowing errors, set time, operating time and assessment.

Material characteristics:
◎ Face skin, neck skin, chest skin, hair, made of imported thermoplastic elastomer mixed rubber material, made of stainless steel mold, high temperature injection pressure by injection molding machine,

形态逼真、外形美观、经久耐用、消毒清洗不变形,拆装更换方便等特点,其材料达到国外同等水平。 It has the characteristics of accurate anatomical marks, real hand feeling, uniform skin color, realistic shape, beautiful appearance, durable, disinfection and cleaning without deformation, and easy disassembly and replacement. Its materials have reached the same level abroad.

Standard set configuration:
◎ An advanced resuscitation human body model
◎ One advanced display controller
◎ Luxury hand-pull human hard plastic box
◎ One resuscitation operation pad
◎ A power adapter
◎ One data cable
◎ Barrier Mask (50 sheets / box)
◎ Four sets of replaceable lung capsule devices
◎ One can be replaced
◎ Two rolls of thermal printing paper
◎ 2015 international latest operating guide CD
◎ A first aid manual
◎ One instruction manual
◎ Warranty card, certificate of conformity

七乐彩 韦德足球 必赢真人娱乐 欢乐拼三张